Art.nr: G-DUAL
The braking forces of the two standard models, G1-2N and G3-3N, are 4460 [N] and 11620 [N] for air-actuated and 5250 [N] and 10400 [N] for failsafe operation, respectively. To release the brake, an air pressure of no more than 6 [bar] is required. Use of this brake is recommended in particular in applications which require greater thermal capacity per unit of surface area. The brake can be installed in any position since it has a lever balancing and lining pad alignment system.
The SG iron clamper is designed to withstand the mechanical and thermal stresses generated in compliance with satisfactory safety coefficients. The lining pads can be adjusted to ensure that the friction surfaces grip the brake disc at all points.
Braking force F | G3-3N: air actuated 11620 N at 6 bar, spring applied 10400 N. G1-2N: air actuated 4460 N at 6 bar, spring applied 5250 N. |
---|---|
Dynamic torque | = F • (disc radius in m - 0.062) = Nm |
Max total wear | 10 mm |
Thickness of new lining | 8 mm |
Continuous thermal capacity Qc | 14 kW |
Minimum release pressure | 5 bar (spring applied) |
The torque values specified are obtained with | n. 8 springs (spring applied) |
Torque proportionally less are achievable with | n. 6-4-2 springs |
Download - Pneumatic Caliper Brakes Brochure.pdf
För reservdelar, kontrollera serienumret på din broms och skicka det till [email protected]. Med serienumret kan vi identifiera alla reservdelar du behöver.
Vi erbjuder Coremo original bromsbelägg, för mer information, kontakta oss på [email protected].